Video Library
Our complete video library can be found Youtube.
Our Products
The SWICKER® Surgical Foam Sponge
The SWIPER® Medical Device Foam Wiper
The SWASHER® Ultra Low-Lint Surgical Towel
The GUIDE-KLIP® Medical Device Retaining Tool
Articles and Presentations by Syntervention
Article published in Endovascular Today, October 2014: Keeping the Room out of the Patient [pdf]
Article published in Endovascular Today, September 2012: Foreign Body Contamination During Interventional Procedures [pdf]
Podium presentation at New Cardiovascular Horizons 6/9/12: Microscopic Foreign Body Contamination during Interventional Procedures [pdf]
Poster presentation from CVPath: Pathologic Identification of Foreign Materials Associated with Cardiovascular Interventional Devices [pdf]
Review of fiber and lint contamination literature: Publication Review of Cotton Fiber Contamination 2025[pdf]
New fiber-free products address an under-recognized danger to patients: The Catastrophic Impact of Cotton Fiber Contamination in Surgical Procedures [pdf]
Additional Supporting Documents
- Bayes-Genis A. Pressure rinsing of coronary stents immediately before implantation reduces inflammation and neointimal hyperplasia. JACC 2001;38(2):562-568.
- Belkin NL. Bacterial Penetration vis-à-vis lint generation. J Hosp Infect. 2002;52(4): 315-7.
- Belkin NL. The role of surgical gowns, drapes, and masks in the generation of airborne particulates. AORN J. 2000;72(4):678-681.
- Beyene RT. Intra-abdominal adhesions. Anatomy, physiology, pathophysiology, and treatment. Curr Probl Surg 2015 Jul;52(7):271-319
- Bookstein JJ. Experimental investigation of hypercoagulant conditions associated with angiography. J Vasc Interv Radiol 1995;6(2):197–204.
- Chapot R. Occlusion of the middle cerebral artery due to synthetic fibers. Am J Neuroradiology 2006;27(1):148–50.
- Chason JL. Cotton fiber embolism, a frequent complication of cerebral angiography. Neurology 1963;13:558-60.
- Chun KC. Infection Following Total Knee Arthroplasty. Knee Surg Relat Res. 2013;25(3):93-99.
- Dimmik JE. Fiber embolization--a hazard of cardiac surgery and catheterization. N Engl J Med. 1975;292(13):685-7.
- di Zerega GS. Contemporary adhesion prevention. Fertil Steril 1994;61,219-35.
- Dragan MJ. Wood fibers from disposable surgical gowns and drapes. JAMA 1979;241:2297-2298.
- Duron JJ. Post-operative peritoneal adhesions and foreign bodies. Eur J Surg 1997;579(Suppl)15-6.
- Duron JJ. Foreign bodies and intraperitoneal post-operative adhesions. J Long Term Eff Med Implants. 1997;7(3-4):235-42.
- Edmiston C. Airborne particulates in the OR environment. AORN J. 1999;69(6): 1169-79.
- Elek SD. The virulence of Staphylococcus pyogenes for man: a study of the problems of wound infections. Br J Exp Pathol.1957;38:573-86. Br J Exp Pathol 1957;38:573-86
- Ellis H. The Causes and Prevention of Intestinal Adhesions. Br J Surg 1982;69(5):241-3.
- Fischi M. Coronary embolization of a gauze fragment: A cautionary case report. Catheterization and Cardiovascular Interventions. 2005;66:570-2.
- Glasgow D. Lint shedding cannot be overlooked. Clinical Services Journal. 2003;Aug: 28-30.
- Headon H. Capsular contraction after breast augmentation: and update for clinical practice. Arch Plas Surg. 2015:42(5):532-43.
- Heath D. Case reports: Cotton-Wool Granuloma of Pulmonary Artery. British Heart Journal 1962;24(4);518-20.
- Holton M. Microscopic foreign body contamination. Abstract presented at: New Cardiovascular Horizons 2012; June 9, 2012; New Orleans, LA.
- Huebner GD. Wood fiber contamination of reusable cotton laparotomy pads. Surgery, Gynecology and Obstetrics. 1979;148(June) 887-889.
- Janoff K. Foreign body reactions secondary to cellulose lint fibers. Am J Surg. 1984;147(5):598-600.
- Jeekel H. Cost implications of adhesions as highlighted in a European study. EUR J Surg Suppl. 1997;579):43-5.
- Laird JR. Foreign Body Contamination During Interventional Procedures. Endov Today. Sept 2012.
- Laird JR. Keeping the room out of the patient: reducing the risk of foreign body embolization procedures. Endov Today. Octo 2014
- Liakakos T. Peritoneal adhesions: Etiology, pathophysiology and clinical significance. Digestive Surg 18:260-273.
- Luijendijk RW. Foreign material in the post-operative adhesions. Ann Surg 1996;223:242-48.
- Menzies D, Ellis H. Intestinal Obstruction from Adhesions--How Big Is the Problem? Ann R Coll Surg Engl 1990; 72(1):60-3.
- Menzies D. Peritoneal Adhesions. Incidence, Cause, and Prevention. Surg Annu 1992; 24Pt 1:27-45.
- Mladicck RA. ”Nor-touch” Submuscular saline breast augmentation technique. Aesthtic Plast Surg. 1993;17(3):183-92.
- Mori H. Catastrophic Consequence of Gauze During Percutaneous Coronary Intervention. JACC 2017; 10(15) e141-142
- Morimoto M. Expansively hemorrhagic foreign body granuloma at the pelvis caused by microscopic materials. Open J Orthopedics. 2012;2:1-5.
- Oloff LM. In Chapter 24 First Metatarsophalangeal Implants pp. 338 in Hetherington V., Hallux Valgus and Forefoot Surgery. 1994 Churchill Livingston Pub. Philadelphia PA., ISBN-13: 978-0443087752.
- Pajkos A. Detection of subclinical infection in significant breast implant capsules. Plast Reconstr Surg 2003;111:1605–11.
- Ramot Y. Foreign Body Granulomas within Intramyocardial Arteries in a Trans coronary Safety Assessment in Pigs. Toxicologic Pathology 2008;36:385-7.
- Sari A. The Potential of Microscopic Sterile Sponge Particles to Induce Foreign Body Reaction. International Wound Journal 2006;3:363-8.
- Shannon P. Inadvertent foreign body embolization in diagnostic and therapeutic cerebral angiography. Am J Neuroradiology 2006;27:278–82.
- Sheldon BK. Cost implications of adhesions as highlighted in a European Study. Eur J Surg Suppl 1997(579);43-5.
- Sheldon BK Intestinal obstruction. AACN Clin Issues. 1999;10(4):478-91.
- Shiino A. [Cotton fiber embolization during angiography: report of a case with histological confirmation]. Neurol Med Chir (Tokyo) 1987;27:443-46.
- Silberman J, Cravioto H, Feigin I. Foreign Body Emboli Following Cerebral Angiography. Archives of Neurology (1960). Vol. 3, 119-26.
- Sturdy JH, Baird RM, Gerein AN. Surgical Sponges: A Cause of Granuloma and Adhesion Formation. Annals of Surgery 1967;165(1):128-34.
- Tinker MA. Granulomatous peritonitis due to cellulose fibers from disposable surgical fabrics: Laboratory investigation and clinical implications. Annals Surg. 1974;180(December):831-35.
- Tinker MA. Cellulose granulomas and their relationship to intestinal obstruction Am J Surg 1
- Truscott W. Infections, Adhesions, Blood Clots, Poor Scar Formation: confirmed role of lint fiber. Outpatient Surgery Magazine's Special Addition: Game Changers, June 2020.
- Truscott W. Impact of microscopic foreign debris on post-surgical complications. Surg Technol International (2004). Vol. 12, 334-46.
- Truscott W. Lint and particle contamination during diagnostic and interventional procedures in the cardiac catheterization lab. Cath Lab Digest (2006). Accessed Feb 2023.
- Truscott W. Patients, Particles, Pathology and Pathogens: Understanding and Avoiding the Risk of Particle-Associated Infection. Managing Infection Control (2009). 94-97.977;133(1):134-39.
- Truscott W. Lint and Fiber-Associated Medical Complications following Invasive Procedures. Biomed Instrument Technol (2023)
- Van Way III, CW. Clinical evaluation of low lint surgical sponge. Surgery, Gynecology and Obstetrics 1982;155(October):529-34.
- Verkkala K. Air contamination in open heart surgery with disposable coveralls, gowns, and drapes. Ann Thorac Surg. 1990 Nov;50(5):757-60.
- Vinters HV. ”Foreign” particles in encephalic vascular malformations. Arch Neurol 1983;40:221-225.
- Von Glahn WC, Hall JW, Sun S. Arteritis in Guinea Pigs, Produced by Emboli of Cotton, Resembling the Arteritis of Hypersensitivity. American Journal of Pathology (1954), Vol. 30, No.6, 1129-1139.
- Walley VM. Foreign Materials Found in the Cardiovascular System After Instrumentation or Surgery (Including a Guide to Their Light Microscopic Identification) Cardiovascular Pathology 1993;2(3):157-85.
- Weinzweig J. Plastic surgery secrets plus. 2nd ed. North Andover, MA: Elsevier; 2010.
- Whelan DM, Foreign Body contamination during stent implantation. Cath Cardiovasc Diagn 1997;40(3):328-32.
- Zimmerli W. Pathogenesis of foreign body infection. J Clin Invest 1984;73:1191-1200